Technical Data | |
---|---|
Overall size of tile (mm) Approximate mass per tile Linear cover per tile |
420 x 332 mm 4.7 - 4.9 kg 300 mm |
Structural Data | |
---|---|
The roof structure specifications should comply with the regulations in your area. |
|
Rafter Centres | |
Up to 760 mm Up to 950 mm |
38 x 38 Batten 38 x 50 mm Batten on edge |
Headlap (mm) | |
17° to 25° 26° and over |
100 75 |
Batten Centres (mm) | |
17° to 25° 26° and over |
320 345 |
Batten per m² (m) | |
17° to 25° 26° and over |
3.13** 2.9** |
Number of tiles per m² | |
17° to 25° 26° and over |
10.42 9.66 |
Approximate mass of tile m² (kg) | |
17° to 25° 26° and over |
± 51 ± 47 |
Undertile Membrane Recommended at all Pitches | |
17° to 25° 26° and over |
Mandatory Recommended |
** No allowance made for wastage. |